Manufacturer’s Description

750VA online, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 13.5 inches. Full-time sine wave 100, 110 or 120V output with +/-2% voltage regulation. Online, double-conversion UPS actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 150. NEMA 5-15P input plug; NEMA 5-15R output receptacles. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Integrated two-bank PDU switching supports load shedding and remote reboot of connected equipment. Dataline surge suppression for dialup, DSL or network Ethernet connection.

The Specs

Additional Specifications
Load Capacity (Watt) 600 W
Bypass Switch Automatic
Network Management SNMP Manageable
Software Included PowerAlert Software
Switching Time 0 ns
Frequency Band Switches: Includes power off/on switch to enable system turn on (press on switch), UPS battery test (press on switch during normal AC operation), buzzer silence (press on switch during battery operation) and off (press off switch) - all switch functions require that the switch be pressed and held for longer than 2 seconds, but less than 4 secondsLow voltage transfer to battery power: Maintains continuous operation during undervoltages as low as 65V (80V at load levels over 70%). Below this switchover point, output is supported from battery-derived AC powerHigh voltage transfer to battery power: Maintains continuous operation without using battery power during overvoltages to 138V. Above this point, output is supported from battery-derived AC powerCold Start: Yes, inverter can be "cold started" to enable temporary AC output during a power failure
Serial Port Yes
Emergency Power OFF Yes
Voltage Handling 2% Output
Brand Name Tripp Lite
Maximum Battery Recharge Time 6 Hour
Backup/Run Time (Full Load) 4 Minute
Overload Protection 15A input breaker
Battery Recharge Time
Hot Swappable Yes
Backup/Run Time (Half Load) 11 Minute
Output Voltage 120 V AC
Rack Height 2U
Load Capacity (VA) 750 VA
Product Line SmartOnline
General
Warranty Information 2 Year
Backup/Run Time 0.07 Hour 600 W Full Load|0.18 Hour 300 W Half Load
URL http://www.tripplite.com
Quick Glance
Power Rating 750 VA/600 W
Input Connectors USB|DB-9 Serial|RJ-45 Dialup Phone/DSL line/Network Ethernet|6 x NEMA 5-15R|NEMA 5-15P
Power
Input Voltage Supported 110 V AC